# for server BTADDR = "00:12:03:27:70:88" SLEEP_TIME = 60 SERIAL_HOST='home.example.com' SERIAL_PORT=1999 DATA_PATH = '/home/matt/templog/web/data' # local config items HMAC_KEY = 'a hmac key' ALLOWED_USERS = [] # list of sha1 hashes of client ssl keys SSH_HOST = 'remotehost' SSH_KEYFILE = '/home/matt/.ssh/somekey' SSH_PROG = 'ssh' UPDATE_URL = 'http://evil.ucc.asn.au/~matt/templog/update' GRAPH_WIDTH = 600 GRAPH_HEIGHT = 700 ZOOM = 1 # determine by viewing the image GRAPH_LEFT_MARGIN = 65 LINE_WIDTH = 2 SENSOR_NAMES = {'sensor_28 CE B2 1A 03 00 00 99': "Old Fridge", 'sensor_28 CC C1 1A 03 00 00 D4': "Old Ambient", 'sensor_28 49 BC 1A 03 00 00 54': "Old Wort", 'sensor_voltage': 'Voltage', 'sensor_fridge_setpoint': 'Setpoint', 'sensor_fridge_on': 'Cool', 'sensor_28-0000042cf4dd': "Wort", 'sensor_28-0000042cccc4': "Fridge", 'sensor_28-0000042c6dbb': "Ambient", 'sensor_internal': "Processor", } # print legend for these ones LEGEND_NAMES = set(("Wort", "Fridge", "Ambient", "Setpoint")) SENSOR_COLOURS = {'Wort': 'e49222', 'Ambient': '028b3d', 'Voltage': '7db5d3aa', 'Fridge': '93c8ff', 'Setpoint': '39c662', 'Cool': 'd7cedd', 'Processor': 'bf7a69', } GRAPH_FONT = "Prociono" #GRAPH_FONT = "URW Gothic L" # 1 hour CSRF_TIMEOUT = 3600 LONG_POLL_TIMEOUT = 500 try: from localconfig import * except ImportError: pass