view py/config.py @ 292:28eb733cb803

60 second timeout
author Matt Johnston <matt@ucc.asn.au>
date Thu, 19 Mar 2015 21:50:52 +0800
parents 251524081924
children d9e81a563923
line wrap: on
line source

import os.path

FRIDGE_SLEEP = 60 # this value works. may affect the algorithm
SENSOR_SLEEP = 15 # same for this.
UPLOAD_SLEEP = 83 # nice and prime

FRIDGE_DELAY = 600 # 10 mins, to avoid fridge damage from frequent cycling off/on
FRIDGE_WORT_INVALID_TIME = 300 # 5 mins

# 12 hours of "offline" readings stored
MAX_READINGS = 12*60*60 / SENSOR_SLEEP

PARAMS_FILE = os.path.join(os.path.dirname(__file__), 'tempserver.conf')

SENSOR_BASE_DIR = '/sys/devices/w1_bus_master1'
FRIDGE_GPIO = '/sys/devices/virtual/gpio/gpio17'
WORT_NAME = '28-0000042cf4dd'
FRIDGE_NAME = '28-0000042cccc4'
AMBIENT_NAME = '28-0000042c6dbb'
INTERNAL_TEMPERATURE = '/sys/class/thermal/thermal_zone0/temp'

HMAC_KEY = "a key"
#UPDATE_URL = 'https://matt.ucc.asn.au/test/templog/update'
UPDATE_URL = 'https://evil.ucc.asn.au/~matt/templog/update'

# site-local values overridden in localconfig, eg WORT_NAME, HMAC_KEY
try:
    from localconfig import *
except ImportError:
    pass